2532 Borton Dr, Santa Barbara, CA 93109, USA
Date of inspection: Dec. 1, 2025
Project: Test Municipality - Sewer Lateral Inspection Program (SLIP) | Test
Inspection #8821
Max Smith
Property Owner
jesseaizenstat@gmail.com
(805) 000-0000
2532 Borton Dr, Santa Barbara, CA 93109, USA
Jesse Aizenstat
Inspector
jesseaizenstat@gmail.com
8057057260
Cojo Canyon Plumbing
- Lic. No.
494932
www.CojoCanyonPlumbing.com
| Observation # | Time | Distance | Code | Municipality Agree |
|---|---|---|---|---|
| Inspector Observation #1 | 0.46 | 33 ft. | COLLAPSE | Yes |
| Inspector Observation #2 | 10.89 | 30 ft. | OFFSET | Yes |
| Inspector Observation #3 | 13.55 | 29 ft. | BROKEN | Yes |
| Inspector Observation #4 | 21.95 | 22 ft. | ROOTS_25 | Yes |
| Inspector Observation #5 | 32.77 | 16 ft. | ROOTS | Yes |
| Inspector Observation #6 | 37.18 | 14 ft. | ROOTS_50 | Yes |
| Inspector Observation #7 | 48.03 | 0 ft. | CLEAN_OUT | Yes |
- Status:
- Submitted
- Submitted:
- Dec. 2, 2025, 5:28 a.m.
- Date of Inspection:
- Dec. 1, 2025
- Time of Inspection:
- 9:24 p.m.
- Project:
- Test Municipality - Sewer Lateral Inspection Program (SLIP) | Test
- Sewer Usage
- Residential
- Camera Direction
- Against Flow
- Pipe Size (inches)
- 4.0
- Total Length (feet)
- 66.0
- Upper Lateral Pipe Material
- Cast Iron
- Lower Lateral Pipe Material
- (VCP) Vitrified Clay Pipe
- Lower Lateral Depth
- Estimated greater than 5 ft
- Is there a cleanout accessible outside of the building?
- Yes
- Does footage include the entire upper and lower lateral?
- Yes
- Is there a cleanout accessible at the sidewalk?
- Yes
- Is there more than one structure on this parcel served by this private sewer lateral?
- No
- Is there more than one sewer lateral on this property?
- No
- Does property have a popper, check valve or another backwater device?
- No
- Has property been verified as having no outside drains connected to the sewer system?
- Yes
- Is this property cross-connected to neighboring parcels?
- No
- Inspector's Summary:
- Some big roots in there and a collapse.
- Signed:
-
Reviewed on: Dec. 2, 2025, 5:32 a.m. by Test Municipality
Your municipality has determined that your sewer lateral on your property needs repair or another inspection. Please review the notes from the municipality and/or the attached letter below for next steps.
Next Steps
If you are the property owner:
Share this inspection with your chosen contractors during the bidding process:Notes from the municipality:
The sewer lateral inspection at 2532 Borton Dr reveals multiple significant defects including a collapse, offset, broken pipe, and extensive root intrusion (25% to 50%) along the lateral. These conditions violate the Santa Barbara Municipal Code requirements for sewer lateral integrity and functionality, which mandate that laterals be free of structural damage and obstructions to prevent sewage leakage and backups.
Due to these defects, the inspection does not pass and the lateral requires repair to comply with municipal standards. The presence of a cleanout accessible outside the building and at the sidewalk is positive, facilitating repair work.
Next steps:
- Get multiple bids with plumbing contractors by forwarding the URL link on Forward Lateral.
- Select a plumbing contractor and pull permits.
- Perform the necessary repairs to address collapse, offset, broken pipe, and root intrusion.
- Schedule or submit a final inspection with the City of Santa Barbara to confirm compliance.