1815 Pampas Ave, Santa Barbara, CA 93101, USA

Date of inspection: Aug. 20, 2025

Project: Test Municipality - Initial Sewer Lateral Inspections

Inspection #8349

Mike Smith
Property Owner
  mike@smith.org
  (805) 679-5949
  1815 Pampas Ave, Santa Barbara, CA 93101, USA
Jesse Aizenstat
Inspector

  jesseaizenstat@gmail.com
  (805) 259-8538
  Cojo Canyon Plumbing - Lic. No. 494932
www.CojoCanyonPlumbing.com

Observation # Time Distance Code Municipality Agree
Inspector Observation #1 3.76 32 ft. COLLAPSE Yes
Inspector Observation #2 12.31 29 ft. BROKEN Yes
Inspector Observation #3 37.33 14 ft. OFFSET No
Corrective Action: Not an offset
Inspector Observation #4 39.65 12 ft. ROOTS Yes
Status:
Submitted
Submitted:
Sept. 2, 2025, 11:53 p.m.
Date of Inspection:
Aug. 20, 2025
Time of Inspection:
2:29 p.m.
Project:
Test Municipality - Initial Sewer Lateral Inspections

Sewer Usage
Residential
Camera Direction
Against Flow
Pipe Size (inches)
4.0
Total Length (feet)
55.0
Pipe Material
Cast Iron
Are repairs needed to the sewer lateral in this inspection?
Yes
Is there a cleanout accessible outside of the building?
Yes
If multiple sewer laterals exist on this property, will the videos be uploaded in this inspection?
No
Does property have a popper, check valve or another backwater device?
No
Is the popper, check valve or another backwater device working?
Yes

Inspector's Summary:
Big collapse. Fix needed.
Signed:

Reviewed on: Sept. 2, 2025, 11:55 p.m. by Test Municipality

Your municipality has determined that your sewer lateral on your property needs repair or another inspection. Please review the notes from the municipality and/or the attached letter below for next steps.

Next Steps

If you are the property owner:

Share this inspection with your chosen contractors during the bidding process:

Notes from the municipality:

The sewer lateral inspection at 1815 Pampas Ave reveals multiple significant defects including collapse, broken pipe, offset joints, and root intrusion, all of which violate Santa Barbara Municipal Code Section 34.324 regarding sewer lateral condition and maintenance standards. The pipe material is cast iron, 4 inches in diameter, with a total length of 55 feet, and the inspection was conducted against flow. The presence of these defects indicates the lateral is not functioning properly and is not up to municipal code requirements.

The City of Santa Barbara has determined that the sewer lateral requires replacement due to these deficiencies. Therefore, the inspection status is Needs Additional Work.

Next steps:
- Get multiple bids with plumbing contractors by forwarding the URL link on Forward Lateral.
- Select a plumbing contractor and pull permits.
- Perform the necessary sewer lateral replacement or repair.
- Schedule or submit a final inspection with the City of Santa Barbara to confirm compliance.